SPECIFICATION / FEATURES:

DC BATT                                  : 12V,180AH (625/800VA), 24V (1200VA/1400VA)


INVERTER O/P VOLT             : 230V (+2%)INV. O/P FREQ : 50Hz 

INV. O/P WAVEFORM             : SINE WAVE (PURE SINE)

CREST FACTOR                       : 4:1

                                                   :80% for 12V system
                                                   : LOW-BATT - FLASH DUURING L.B ALARM
                                                   - PERMANENT GLOW DURING CUT
                                                   : OVER LOD - FLASH DUURING O.L ALARM
                                                   - PERMANENT GLOW DURING CUT
                                                   : CHARGING - FLASH DURING CHARGING
                                                   - PERMANENT GLOW DURING ABSORPTION
                                                   : MAIN - MAIN ON


INV.EFFICIENCY                    : 90% for 24V system

INV. PROTECTION                 : LO-BATTERY SHUT
                                                   : OVER LOAD SHUT
                                                   : O/P SHORT CKT SHUT
                                                   : LO-BATTERY : BEEP START AT 10.5V (BEEP@ EVERY 
                                                     3- SEC) INV SHUT DOWN AT 10V (5XBEEP at every 2-SEC)
                                                  : OVER LOAD : BEEP START AT 120% LOAD (BEEP at every 2 sec)
                                                  INV. SHUT DOWN AT 130% LOAD (5XBEEP at every 2-SEC)

LED INDICATION                 : INVERTER ON

CIRCUIT                                 : 8-BIT MICROCONTROLLER BASED CONTROL CIRCUIT
                                                 : H-BRIDGE INVERTER OPERATION
                                                 : MOSFET SWITCHING FAULT DET

 CHARGING ALGORITHM : MOSFET based PWM SMPS CHARGE CONTROLLER 5A to 15A
                                                : 2-STEP CHARGING STEP-1: BOOST MODE (LED FLASH)
                                                  STEP-2: ABSORPTION MODE (LED ON)

DC FAN                                  : FOR INTERNAL COOLING DURING CHARGING/IN OPERATION